Sooting Yale Coflow Diffusion Flames


Condition C
Ethylene Sooting Flame 60% fuel diluted with nitrogen, nonsmoking

Fuel: Ethylene/N2
Oxidizer: Air
Fuel velocity: 35 cm/s (cold-flow velocity)
Oxidizer velocity: 35 cm/s (cold-flow velocity)
Recommended T boundary condition: see BC60.txt below.
Recommended computational domain: At least 10 cm above the fuel tube exit plane and at least 7.5 cm in the radial direction. At least 15,000 non-equispaced control volumes with careful attention paid to grid independence, tolerance independence, and domain length independence.

The data is in a tab delimited, formatted text file, consisting of a two-dimensional array of floating point values. The matrix represents an image with pixel spacing of 0.1 mm (10 pixels/mm). The first element of the matrix corresponds to the value in the upper left corner of the images shown. This type of data can be read in directly to Matlab using the 'load' command.



Soot Temperature based on color ratio pyrometry using a Nikon D90 camera. Data was published in Ref. 6. Here, soot optical properties were assumed to be constant throughout the flame with the emissivity varying with wavelength to the -1.38 power.

The data array size is 901 x 201.

T60D90.txt


Soot Volume Fraction based on color ratio pyrometry using a Nikon D90 camera. Data was published in Ref. 6. Here, soot optical properties were assumed to be constant throughout the flame with the emissivity varying with wavelength to the -1.38 power.

The data array size is 901 x 201.

Fv60D90.txt



Soot Volume Fraction based on LII and calibrated using absorption. Data was published in Refs 3-6. Soot optical properties were assumed to be constant throughout the flame with Kext = 8.6.
 
The data array size is 901 x 201.

Fv60LII.txt


The effective radius of gyration of mature soot aggregates was measured using multi-angle light scattering (MALS) at 532 nm. The experiment was detailed and published in Ref. 13. The effective radius of gyration is a function of aggregate size and polydispersity.

The data array size is 900 x 200.

Rg_eff_60.txt


60% flame near-burner temperature. The experiment was detailed and published in Ref. 14.

The data array size is 2 x 60 (r [mm], T [K]).

BC60.txt